Fire Sprinkler Valve Acceptance Class

  • Thursday, September 26, 2024
  • 09:00 - 14:00
  • UA Local 699 - South Seattle College - Georgetown Campus
  • 0

Registration

  • Includes lunch and certificate. Registration fee is non-refundable.

Fire Sprinkler Valve Class

Presented by UA Local 699

September 26, 2024

South Seattle College- Georgetown Campus 6737 Corson Avenue South - Building B119, Seattle, 98108

09:00-14:00hrs


Cost $25.00

(Includes Certificate and Lunch)


The primary focus of this class will be what to expect and look for during a Fire Sprinkler Valve Acceptance test


Course Outline:  This presentation will provide a description of acceptance testing on Wet, Dry, Pre-action, and Deluge systems, in addition we will review these key items.

  • Understanding and interpreting the Contractors Materials and Test Report for Above Ground Piping and its importance.
  • Hands on understanding of the basic components for each valve type and their purpose for the system type.
  • Demonstrate at each of the valve stations what they would expect to see during a final and how each component needs to be tested and recorded in order to properly gain all the date to fill out the test report, as well as giving you the ability to hands on go through these motions with our valves.


Class will be limited to a maximum of 15 attendees.

ICC credit will be issued.


Special Instructions:

There will be a small amount of classroom time to start and then the remainder out in the shop. Dress should be appropriate duty uniform and duty boots to avoid wet feet.


Class Contact: Donnie Reese (206) 940-4919       Email: Donnie@ualocal699.org


Instructors:

Steve Miller - Training Director for UA Local 699's apprenticeship & Instructor, Prior foremen at McKinstry, ASSE 15000 ITM instructor and proctor, UA Special hazards systems instructor, UA Instructor Graduate, UA Training Directors program graduate, Licensed Washington state fitter, Passed NICET 2 ITM, Passed NICET water based systems layout LVL 2, Victaulic Valve “train the trainer” instructor, Victaulic Grooving Essentials “Train the Trainer” instructor, OSHA Authorized Construction Trainer and Disaster Site Worker


Ricky Campbell - Business agent for UA Local 699 Sprinkler Fitters. Instructor at UA Local 699 Sprinkler Fitters. Past service foreman at McKinstry Fire Protection. NICET 2 ITT, ASSE 15000 instructor and proctor, UA Instructor Graduate.


Donnie Reese- Assistant Training Director & Instructor for UA Local 699 apprenticeship, Washington state licensed Sprinkler fitter, Prior foremen and Emerald Fire,  ASSE 15000 ITM Instructor and proctor, NICET 2 ITM, OSHA Authorized Construction Trainer and Disaster Site Worker.

Washington State Association of Fire Marshals

Address: 605 11th Ave SE, Suite 211, Olympia WA, 98501

(360) 352-0161 email:  wsafm@wsafm.com

© 2019 Washington State Association of Fire Marshals. All Rights Reserved.

Our Partners in Community Risk Reduction


Powered by Wild Apricot Membership Software